Modular gas boilers

Water tube boilers are designed as flow-through, overpressure self-supporting boilers. They have a low water volume, which makes them highly flexible and allows them to quickly respond to changes in the required thermal power. With their reduced thermal volume, they can be promptly commissioned.
HBW30 | Technical parameters

 

Rated continuous boiler power
30 MWt
Minimum continuous boiler operation
6 MWt
Boiler performance range
1 : 5
Minimum energy conversion efficiency of the boiler
95%
Minimum water temperature at the boiler inlet
65ºC
Heating value
35.8 MJ/Nm3
Gas flow
3165 Nm3/h
HBW15 | Technical parameters

 

Rated continuous boiler power
15 MWt
Minimum continuous boiler operation
3 MWt
Boiler performance range
1 : 5
Minimum energy conversion efficiency of the boiler
95%
Minimum water temperature at the boiler inlet
65ºC
Heating value
35.8 MJ/Nm3
Gas flow
1583 Nm3/h

Ergonomics is not just about comfort.

The control cabinet is designed for ergonomic use, with a particular focus on:

  • arrangement of the screen and pushbuttons
  • logical layout of components to prevent erroneous use
  • intuitive and legible marking.

Controls

To allow safe and convenient use of the controls, they were designed with a special focus on their ergonomics. The sizes of the controls, diameters of the handles, and their heights are all essential features.

Manhole

To ensure the highest possible convenience when opening a manhole with gloves, the handle has a length of 150 mm and a diameter of 33 mm. The handle also features a rubber covering.

Peep hole

This is located 155 cm off the ground or a platform.

Marking system

Rating plates are designed in a clear and simple manner, ensuring that their layout does not distract from the important data. The plate is large so that it can be read from the distance required when accessing a boiler. The height of its location considers the ergonomics as well as the platform height.

Modular platform and stair system

With this system, we can design stairs and platforms of various sizes, adapted to the current needs. It is based on several modules that allow the design of safety railings of various combinations and sizes.

The design is based on ergonomics and the provisions contained in ISO 14122 (Safety of machinery — Permanent means of access to machinery). It also facilitates transport and installation.

UE logo